Research Article

Sensitivity Evaluation of AP1000 Nuclear Power Plant Best Estimation Model

Table 14

The influence of feedwater temperature on the steam output.

Feedwater temperature (K)Calculated steam output (kg/s)Designed steam output (kg/s)Fractional error

494.85970.2943.61112.818%
496.85970.19943.61112.817%
499.85970.18943.61112.816%
502.85970.18943.61112.816%
504.85970.17943.61112.815%