The influence of core channel number on the reactor pressure drop.

Core channel numberReactor inlet pressure (MPa)Reactor outlet pressure (MPa)Calculated reactor pressure drop (MPa)Designed reactor pressure drop (MPa)Fractional error

115.822315.41230.41000.434.65%
315.825015.41660.40840.435.02%
515.834215.42130.41290.433.98%
1015.89115.60850.28250.4334.30%
2015.864715.51250.35220.4318.09%