Science and Technology of Nuclear Installations / 2018 / Article / Tab 4

Research Article

Numerical Simulation of Decontamination of Airborne Fission Products during In-Vessel Release Phase by Containment Spray

Table 4

Numerical data for spray removal term [31, 35, 36].

ParameterSymbolValue

Partition coefficient200 (pH 5.0), 5000 (pH 9.5) 10,000 (Na2S2O3)
Reynolds numberRe1.29
Schmidt numberSc1.742
Molar weights of solvent (g/mole)18.01528
Temperature (K)80 + 273.15
Molecular volume of (cm3/g)71.5
Viscosity (centipoise)0.35
Spray flow rateF (m3/sec)0.35
Degree of solvent2.6 for H2O

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.