Research Article
Process of Air Ingress during a Depressurization Accident of GTHTR300
Table 5
Positions of temperature measurement.
| Gas temperature in the experimental apparatus of double coaxial cylinder | No. | Distance from bottom [mm] | Distance from outer cylinder [mm] | Diameter |
| 1 | 337.5 | 5 | φ1 | 2 | 337.5 | 5 | φ1 | 3 | 337.5 | 16.5 | φ1 | 4 | 337.5 | 16.5 | φ1 | 5 | 337.5 | 28 | φ1 | 6 | 337.5 | 28 | φ1 | 7 | 205 | 5 | φ1 | 8 | 205 | 5 | φ1 | 9 | 205 | 16.5 | φ1 | 10 | 205 | 16.5 | φ1 | 11 | 205 | 28 | φ1 | 12 | 205 | 28 | φ1 | 13 | 72.5 | 5 | φ1 | 14 | 72.5 | 5 | φ1 | 15 | 72.5 | 16.5 | φ1 | 16 | 72.5 | 16.5 | φ1 | 17 | 72.5 | 28 | φ1 | 18 | 72.5 | 28 | φ1 | 21 | 25 | 38.7 | φ1 | 22 | 25 | 38.7 | φ1 | 23 | 25 | 38.7 | φ1 | 24 | 25 | 38.7 | φ1 | 25 | 25 | 38.7 | φ1 | 26 | 25 | 38.7 | φ1 | 31 | 410 | 19.7 | φ1 | 32 | 410 | 19.7 | φ1 | 33 | 410 | 19.7 | φ1 | 34 | 410 | 19.7 | φ1 | 35 | 410 | 19.7 | φ1 | 36 | 410 | 19.7 | φ1 | 37 | 410 | 83.7 | φ1 | 38 | 310 | 83.7 | φ1 |
| Temperature of cooling water and cartridge heater | 19 | Cooling water inlet | φ1 | 20 | Cooling water outlet | φ1 | 27 | Cartridge heater 1 | φ1 | 28 | Cartridge heater 2 | φ1 | 29 | Cartridge heater 3 | φ1 | 30 | Cartridge heater 4 | φ1 |
|
|