ROSA/LSTF Tests and Posttest Analyses by RELAP5 Code for Accident Management Measures during PWR Station Blackout Transient with Loss of Primary Coolant and Gas Inflow
Table 1
Major conditions of LSTF tests.
Item
Condition
TR-LF-18
TR-LF-17
TR-LF-16
Break size
0.5%
0.2%
0.1%
Break location
Side of cold leg
Top of cold leg
Break valve open
Time zero
High-pressure injection system
Total-failure
Onset of SG secondary-side depressurization by fully opening relief valves in both SGs
10 min after break
20 min after break
Time zero
Onset of AFW injection into secondary-side of both SGs
Concurrent with SG secondary-side depressurization