Research Article
Study of Fast Transient Pressure Drop in VVER-1000 Nuclear Reactor Using Acoustic Phenomenon
Table 1
VVER-1000 geometry and operating conditions [
18].
| Operating condition | Value |
| Core height in the working state (cm) | 355 | Rod diameter (mm) | 9.1 | Pitch (mm) | 12.75 | Fuel pellet material | UO2 | Number of fuel rods in the fuel assembly | 311 | Average linear heat rate (W/cm) | 166.7 | Coolant flow rate (m3/h) | 84800 | Inlet pressure (MPa) | 16 | Outlet pressure (MPa) | 15.70 | Temperature at the inlet (°C) | 291 |
|
|