Research Article
Research of PWR Pressurizer Insurge Characteristics on Three-Dimensional Transient Modeling
Table 1
Basic design parameters of different PWR pressurizers.
| Parameters | CPR1000 | AP1000 | AP600 | EPR1000 |
| Design pressure (absolute), MPa | 17.23 | 17.23 | 17.23 | 17.23 | Design temperature, °C | 360 | 360 | 360 | 360 | Operating temperature, °C | 345 | 345 | 345 | 345 | Operating pressure (absolute), MPa | 15.5 | 15.5 | 15.5 | 15.5 | Total volume, m3 | 39.75 | 59.47 | 45.28 | 75 | Spray flow, m3/h | 151~200 | 159 | 159 | / | The inner diameter of cylinder, m | 2.134 | 2.54 | 2.54 | 2.431 | Height, m | 13 | 15.4 | 11.97 | 14 | The inner diameter of Surge line, m | 0.284 | 0.366 | / | 0.326 | Volume/reactor power, m3/M | 1.5×10−2 | 1.75×10−2 | 2.33×10−2 | 1.67×10−2 |
|
|