Research Article

Validation of the COTENP Code: A Steady-State Thermal-Hydraulic Analysis Code for Nuclear Reactors with Plate Type Fuel Assemblies

Table 2

Temperature results obtained with the COTENP code for the IEA-R1 reactor at different power levels. Temperature results simulate measurement results at different locations of the IFA. The IFA is located at the (6,8) position. Inferred error from experimental results is + 0.25°C or + 0.5 %.

Temperature (°C)
Power level = 4 MWPower level = 4.5 MWPower level = 5 MW
Experimental COTENPDiscrepancy (%)ExperimentalCOTENPDiscrepancy (%)ExperimentalCOTENPDiscrepancy (%)

TC244.4143.601.846.4745.502.148.7247.602.3
TC337.2841.201038.6842.901140.3044.8011
TC445.2742.705.747.2944.356.249.5746.506.2
TC549.2549.350.251.7851.800.154.5654.300.5
TC642.9545.856.744.8748.00747.0150.256.9
TC750.5148.054.953.0250.255.255.8552.755.5
TC845.9946.451.048.2248.751.150.6950.950.5
TC1042.0243.553.642.8145.456.244.9047.606.1
TC1247.6445.304.943.9247.40846.0849.657.7
TF1437.2836.711.538.7038.101.640.3439.152.9

Root Mean Square Discrepancy (%)4.14.85.0