Main description parameters of IEA-R1 research reactor [22, 26].

Reactor parameterDataNote

Thermal power reactor [MW]2-5Depends on irradiation program
Number of Fuel assembly24
  (i) Standard FA20
  (ii) Control FA4
Total coolant flow rate [m3/h]772
 Bypass flow rate [m3/h]547.2
 Coolant flow rate of FA [m3/h]22.8
Inlet Pressure [Mpa]0.17
Inlet temperature [°C]31.67/32.50/ 32.53For 4.0 / 4.5 /5.0 [MW] respectively
Power Density [W/cm3]143 /158 /172For 4.0 / 4.5 /5.0 [MW] respectively
Number of fuel plates:
 (i) Standard FA18
 (ii) Control FA12
Fuel meat dimensions (U3Si2-Al or U3O8-Al) [mm]0.76 x 62.6 x 600
Thickness of coolant channel [mm]2.89
Clad thickness[mm]0.38