Research Article

Standalone Containment Analysis of Four Phébus Tests with the ASTEC and the MELCOR Codes

Table 2

Phase subdivision and timings of the Phébus FPT tests.

Phases
TestDegradationAerosolWashingChemistryEnd of test

FPT-00 s20,438 s / 5.67 h111,218 s / 30.9 h112,118 s / 31.1 h433,848 s / 120.5 h

FPT-10 s17,039 s / 4.73 h250,000 s / 60.4 h251,260 s / 69.8 h341,400 s / 94.8 h

FPT-20 s24,240 s / 6.73 h157,140 s / 43.7 h177,060 s / 49.2 h375,780 s / 104.4 h

FPT-30 s22,500 s / 6.25 h151,920 s / 42.2 h184,440 s / 51.2 h386,340 s / 107.3 h