Research Article

Multilayer Shielding Design for Intermediate Radioactive Waste Storage Drums: A Comparative Study between FLUKA and QAD-CGA

Table 2

The cutoff energy and Russian roulette splitting setting.

regionscutoff energysplitting number

the standard 200L steel drum1 keV4

the cement inner shielding layer9 keV2

the auxiliary support structure9 keV2