Studies on Key Effect Factors of Natural Circulation Characteristics for Advanced PWR Reactor Cavity Flooding System
Table 1
Key parameters of REVECT facility.
| Parameters | Value/definition | Remarks |
| Test pressure | Atmosphere | Pressure in upper water tank | Water temperature at inlet of test section | ∼100°C | The saturation temperature corresponds to the pressure of the upper water tank | Target water level of the upper water tank | 7300 mm | The elevation of the bottom of the heating section is selected as the 0 m level, the same as the prototype | Elevation of steam exhaust port | 8000 mm | Relative to the bottom of the heating section | Circulation type | Natural circulation | The same as the prototype | Working fluid | Deionized water | | Steam/water outlet area of the upflow pipe | ∼0.01 m2 | About 1/100 of the prototype RPV insulation steam invent port area | Cooling water inlet area of the test section | ∼0.01 m2 | About 1/100 of the prototype RPV insulation cooling water inlet port area | Structure of baffles | 3-part multilateral structure | With the same structure and “gap size” distribution as the prototype | Circulation resistance | Scaling as the prototype to ensure the consistence of the comprehensive resistance of facility and the prototype | Based on the geometry and resistance distribution analysis of the prototype flow path |
|
|