Research Article
Studies on Key Effect Factors of Natural Circulation Characteristics for Advanced PWR Reactor Cavity Flooding System
Table 3
Test conditions for the flow channel optimization.
| No. | Test types | Minimum distance of flow channel L1/L2 | Temperature of the inlet | Pressure |
| 1 | Flow channel optimization test FC01 | 250/250 mm | ∼100°C | 1 bar | 2 | Flow channel optimization test FC02 | 250/210 mm | ∼100°C | 1 bar | 3 | Flow channel optimization test FC03 | 250/140 mm | ∼100°C | 1 bar | 4 | Flow channel optimization test FC04 | 200/200 mm | ∼100°C | 1 bar | 5 | Flow channel optimization test FC05 | 200/180 mm | ∼100°C | 1 bar | 6 | Flow channel optimization test FC06 | 200/130 mm | ∼100°C | 1 bar | 7 | Flow channel optimization test FC07 | 150/150 mm | ∼100°C | 1 bar | 8 | Flow channel optimization test FC08 | 150/145 mm | ∼100°C | 1 bar | 9 | Flow channel optimization test FC09 | 150/100 mm | ∼100°C | 1 bar |
|
|