Research Article

Studies on Key Effect Factors of Natural Circulation Characteristics for Advanced PWR Reactor Cavity Flooding System

Table 3

Test conditions for the flow channel optimization.

No.Test typesMinimum distance of flow channel L1/L2Temperature of the inletPressure

1Flow channel optimization test FC01250/250 mm∼100°C1 bar
2Flow channel optimization test FC02250/210 mm∼100°C1 bar
3Flow channel optimization test FC03250/140 mm∼100°C1 bar
4Flow channel optimization test FC04200/200 mm∼100°C1 bar
5Flow channel optimization test FC05200/180 mm∼100°C1 bar
6Flow channel optimization test FC06200/130 mm∼100°C1 bar
7Flow channel optimization test FC07150/150 mm∼100°C1 bar
8Flow channel optimization test FC08150/145 mm∼100°C1 bar
9Flow channel optimization test FC09150/100 mm∼100°C1 bar