Research Article

Inerting Strategy for a Demonstration-Scale Hot Cell Facility Based on Experiences from Pilot-Scale Argon Cell Facility Operation and CFD Analysis

Table 2

Comparison of PRIDE and the target facility of this study (for regular operation).

Design parameterPRIDETarget facility

Cell volume1,230 m37,560 m3
No. of inlet ports20106
Shape of inlet portCircularSquare
Area of inlet port0.033 m20.1008 m2
Space between inlet portsNot identified1.261 m
No. of outlet ports1474
Shape of outlet portRectangularRectangular
Area of outlet port0.3024 m20.3024 m2
Space between outlet portsNot identified0.952 m