Investigation of Loss of Feedwater (LOFW) Accident in the APR-1400 Using Fault Tree Analysis
Table 1
Component unreliability of the main feedwater system.
| Basic event | Component code | NUREG-6928 /IAEA-478 | WASH-1400 | Mean | Mean |
| Check valve fails to open | A, AI, AH, F, K, P | 1.30E − 05/d | 1.00E − 04/d | Control valve fails to open | AE | 2.50E − 02/d | 1.00E − 03/d | HP feedwater heater failure | AA, AB, T, V, W, Y | 1.30E − 05/h | 7.10E − 04/h | Hydraulically operated MFIV fails to open | AF, AG | 1.51E − 03/d | 3.00E − 04/d | Large leak from the deaerator storage tank | B | 2.75E − 09/h | 1.00E − 10/h | Motor-driven booster pump fails to run | D, I, N | 4.54E − 06/h | 3.00E − 05/h | Motor-driven bypass line isolation valve fails to open | AD | 1.07E − 03/d | 1.00E − 03/d | Motor-driven inlet isolation valve fails to open | U, Z | 1.07E − 03/d | 1.00E − 03/d | Motor-driven outlet isolation valve fails to open | AC, X | 1.07E − 03/d | 1.00E − 03/d | Motor-driven startup pump fails to start | S | 2.23E − 03/d | 1.00E − 03/d | Pipe rupture >3″ in diameter | AJ | 1.00E − 10/h | 1.00E − 10/h | Total loss of offsite power | C | 4.10E − 06/h | 1.00E − 05/d | Turbine-driven main feedwater pump fails to run | E, J, O | 5.77E − 06/h | 3.00E − 05/h |
|
|