Research Article

Fundamental Frequencies of Vibration of Footbridges in Portugal: From In Situ Measurements to Numerical Modelling

Table 7

Comparison of frequencies (Hz) between measurements in  situ and the analytical model.

Mode directionMeasurements in  situ Analytical model

Longitudinal2.77 2.77
Vertical3.79 3.34
Transversal 3.73 3.73
Torsion about (vertical)?5.71
Torsion about (longitudinal)7.91 8.80