Research Article

Feasibility Verification of Mountable PZT-Interface for Impedance Monitoring in Tendon-Anchorage

Table 1

Material properties of cable-anchorage connection.

ParametersPZT-interfaceBearing plate and anchor head

Young’s modulus, (GPa)70 200
Poisson’s ratio, 0.330.3
Mass density, (kg/m3)2700 7850
Damping loss factor, 0.0010.02