Research Article
Automatic Condition Monitoring of Industrial Rolling-Element Bearings Using Motor’s Vibration and Current Analysis
Table 1
Statistical evaluation of vibration measurements.
| Scenario | Mean | Variance | MD (%) | VD (%) |
| 50 Hz, Nom | 0.3473 | 0.0846 | | | 50 Hz, Inner | 0.3478 | 3.1295 | 0.14 | | 50 Hz, Outer | 0.3482 | 873.7352 | 0.26 | | 50 Hz, Lub. | 0.3775 | 0.2715 | 0.87 | |
| 40 Hz, Nom | 0.3474 | 0.0597 | | | 40 Hz, Inner | 0.3484 | 2.0753 | 0.29 | | 40 Hz, Outer | 0.3483 | 303.3030 | 0.26 | |
| 20 Hz, Nom | 0.3487 | 0.0116 | | | 20 Hz, Inner | 0.3483 | 0.3039 | −0.11 | | 20 Hz, Outer | 0.3488 | 13.3662 | 0.01 | |
|
|