Research Article
Identifying the Mechanical Parameters of Hard Coating with Strain Dependent Characteristic by an Inverse Method
Table 6
The 6th order resonant frequencies, resonant responses, and modal damping ratios of uncoated and coated plate under different excitation levels.
| Excitation level (g) | 1 | 2 | 4 | 6 |
| Uncoated plate | Resonant frequency (Hz) | 1297.08 | 1297.00 | 1297.00 | 1297.05 | Resonant response (μm) | 13.5 | 31.4 | 68.1 | 96.3 | Modal damping ratio (%) | 0.11 | 0.11 | 0.11 | 0.11 |
| Coated plate | Resonant frequency (Hz) | 1263.13 | 1261.88 | 1259.13 | 1258.13 | Resonant response (μm) | 6.3 | 12.0 | 22.8 | 33.1 | Modal damping ratio (%) | 0.25 | 0.26 | 0.27 | 0.28 |
|
|