Research Article
Online Structural Health Monitoring and Parameter Estimation for Vibrating Active Cantilever Beams Using Low-Priced Microcontrollers
Table 2
Summary of estimated results (mean estimates at
= 50–60 s).
| Number | Weight | Detected | (Hz) | (kg) | (Nm−1) | (Nsm−1) | (NkV−1) |
| 1 | 0 g | ✗ | 2.26 | 0.42 | 83.8 | 1.7 | 0.5 | 2 | 16 g | 76.5 s | 2.23 | 0.42 | 83.2 | 1.8 | 0.5 | 3 | 50 g | 49.2 s | 2.20 | 0.44 | 83.8 | 1.8 | 0.4 | 4 | 99 g | 46.1 s | 2.11 | 0.47 | 82.9 | 1.7 | 0.4 | 5 | 195 g | 44.4 s | 1.98 | 0.56 | 86.9 | 1.9 | 0.4 | 6 | 246 g | 41.7 s | 1.91 | 0.60 | 86.5 | 2.2 | 0.3 | 7 | 345 g | 39.9 s | 1.81 | 0.61 | 79.0 | 1.9 | 0.2 |
|
|