Research Article

Forced Responses of the Parametric Vibration System for the Electromechanical Integrated Magnetic Gear

Table 1

Parameters of example EIMG system.

Number of pole pairs on the inner surface of the inner rotor5Number of pole pairs on the inner stator2
Number of pole pairs on the outer surface of the inner rotor4Number of pole pairs on the outer stator17
Number of the inner ferromagnetic pole-pieces7Number of the outer ferromagnetic pole-pieces21
Outer radius of the inner stator/mm98Inner radius of the inner FP/mm100
Outer radius of the inner FP/mm130Thickness of PMs on the inner rotor/mm10
Inner radius of the inner rotor yoke/mm152Outer radius of the inner rotor yoke/mm182
Inner radius of the outer FP/mm204Outer radius of the outer FP/mm234
Thickness of PMs on the outer stator/mm10Inner radius of the outer stator yoke/mm256
Outer radius of the outer stator yoke/mm276Axial length/mm40
Remanence of PMs/T1.3Coercive force of PMs/KOe11.6
Magnitude of currents on the inner stator/A20Current frequency/Hz50