Research Article
Performance Improvement of Ensemble Empirical Mode Decomposition for Roller Bearings Damage Detection
Table 2
The success rates of damage detection using the proposed algorithm (PIEEMD) in
direction.
| SNR | 100 Hz 1.0 kN | 100 Hz 1.4 kN | 100 Hz 1.8 kN | 200 Hz 1.0 kN | 200 Hz 1.4 kN | 200 Hz 1.8 kN | 300 Hz 1.0 kN | 300 Hz 1.4 kN | 300 Hz 1.8 kN | 400 Hz 1.0 kN | 400 Hz 1.4 kN | 400 Hz 1.8 kN |
| 5 | 100 | 100 | 81.3 | 100 | 87.5 | 73.3 | 100 | 100 | 100 | 100 | 100 | 100 | 10 | 100 | 100 | 100 | 100 | 100 | 87.5 | 100 | 100 | 100 | 100 | 100 | 100 | 15 | 100 | 100 | 93.8 | 100 | 100 | 93.8 | 100 | 87.5 | 100 | 100 | 100 | 100 | 20 | 100 | 100 | 87.5 | 100 | 100 | 100 | 100 | 87.5 | 100 | 100 | 100 | 100 | 25 | 100 | 100 | 81.3 | 100 | 100 | 93.8 | 100 | 87.5 | 100 | 100 | 100 | 93.8 | 30 | 100 | 100 | 81.3 | 100 | 100 | 93.8 | 100 | 87.5 | 100 | 100 | 100 | 93.8 |
|
|