Shock and Vibration / 2016 / Article / Tab 3

Research Article

Fuzzy Robust Design of Dynamic Vibration Absorbers

Table 3

Optimization results obtained by the DVA design problem.

Approach [N/m] [Ns/m]Cost functionRobustness

Deterministic96.27441.95500.000024.2396
Dual optm.96.23712.04740.002023.4711
Amplitude min94.61592.19581.713122.0145
Fuzzy response95.43662.17940.823522.2918