Research Article

Structural Modifications for Torsional Vibration Control of Shafting Systems Based on Torsional Receptances

Table 4

Obtained frequencies and required structural modifications.

ParameterInitial valueObtained value

Moment of inertia [kg⋅m2]5.55.15
3.52.65

Stiffness [kN⋅m]400800.01

Desired mode number, GoalProposed methodError

[Hz]13030.010.01
39090.020.02

1−0.4765−0.47660.0001
−0.9432−0.9431−0.0001

3110
−0.1513−0.1512−0.0001