Research Article

Fractal Model for Acoustic Absorbing of Porous Fibrous Metal Materials

Table 4

The calculated and measured static flow resistivities of different tortuosity fractal dimensions.

Number Sample #1 Sample #2 Sample #3
Static flow resistivity
σ (Nm−4s)
Measured
value
σ (Nm−4s)
Deviation
(%)
Static flow
resistivity
σ (Nm−4s)
Measured value
σ (Nm−4s)
Deviation
(%)
Static flow
resistivity
σ (Nm−4s)
Measured value
σ (Nm−4s)
Deviation
(%)

#11.02837379875615.2131233346559.871667719748 15.55
#21.05933815.44346840.08183667.00
#31.071004101.67371907.3119584 8.30
#41.081041205.433851011.12202232.41
#51.1011196013.374128919.14215649.20
Mean value1.06968341.95359153.63189653.96