Abstract

The combined use of two emerging technologies in the field of seismic engineering is investigated. The first is a semiactive control, to reduce smartly the effects induced by earthquakes on structures. The second is the Seismic Early Warning System which allows an estimate of the Peak Ground Accelerations of an incoming earthquake. This paper proposes the exploitation of this information in the framework of a semiactive control strategy based on the use of magnetorheological (MR) dampers. The main idea consists of changing the MR dampers’ behaviour by the PGA estimated by the SEWS, to obtain the optimal seismic response of the structure. The control algorithm needed to drive the variable devices, according to the PGA estimate, is the core issue of the proposed strategy. It has been found that different characteristics of earthquakes that occur at different sites play a significant role in the definition of a control algorithm. Therefore, a design procedure for “regional” control algorithms has been performed. It is based on the results of several nonlinear dynamic simulations performed using natural earthquakes and on the use of a multicriteria decision-making procedure. The effectiveness of the proposed control strategy has been verified with reference to a highway bridge and to two specific worldwide seismic regions.

1. Introduction

Earthquakes represent one of the most destructive natural hazards. Among the possible serious consequences of a large-magnitude earthquake is the disruption of transportation systems, which limits postdisaster emergency response. The movement of emergency vehicles, such as police cars, fire trucks, and ambulances, can be severely restricted. Bridges have suffered various types of damage in past earthquakes, such as during the San Fernando (1971), Loma Prieta (1989), and Northridge (1994) earthquakes in California, the Kobe Earthquake (1995) in Japan, the Chi Earthquake (1999) in Taiwan, the Darfield (2010) and Christchurch (2011) Earthquakes in New Zealand, the Maule (2010) Earthquake in Chile, and the Tohoku (2011) Earthquake in Japan. Several types of damage have been recorded, sometimes affecting a few components, and in some cases leading to the overall structural collapse. A virtually complete collection of information related to the structural, social, and economic consequences on bridges (and other structures) due to earthquakes worldwide over the past 40 years can be found in the EERI archive that is part of the Learning from Earthquake Program [1].

Much research over the last few decades has been devoted to the definition of innovative techniques to address the seismic design and retrofit of bridges. In particular when dealing with the structural improvement of existing bridges in densely built earthquake-prone regions, the decision strategy for selecting the optimal intervention should not be based on the concept of seismic vulnerability alone and rather should take into account the cost-benefit balance of upgrade measures.

Most of the recent research contributions regarding the seismic upgrade of bridges have been stimulated by the international challenge launched in [24]. From 2009 to the present, several options of intervention have been proposed by the researchers in the field with reference to the benchmark structure defined in those articles. The final outcome is a wide range of alternative approaches, all appreciably innovative and effective in reducing the structural response of that highway bridge. They belong to all the three families of passive, semiactive, and active control techniques. Jung et al. [5] investigated the effectiveness of an adaptive passive control system based on magnetorheological (MR) dampers and on the concept of Electromagnetic Induction (EMI) proposed by Cho et al. [6]. Pradono et al. [7] proposed a simple control approach to produce negative stiffness hysteretic loops to reduce the vibration of base isolated bridges with MR dampers. A new control design approach to monitor the voltage supplied to MR dampers was developed by Ali and Ramaswamy [8]. Casciati et al. [9] applied a Passive Shape Memory Alloy Device (PSMAD), incorporating the analytical model of the structure in the control force equation of sample passive devices. An upgraded version of the PSMAD was subsequently elaborated by Zhang et al. [10], employing superelastic alloy wires with self-centring capabilities to use these damping devices in outdoor environments, especially in cold regions. Pujol et al. [11] used a passive static hyperbolic function depending only on velocity to ensure energy dissipation capabilities with a bounded control force. Ning et al. [12] developed an adaptive fuzzy sliding mode control algorithm for active actuators and then adapted the concept for use in combination with semiactive MR dampers. The dynamic behaviour of the benchmark bridge using three additional control strategies based on linear viscous dampers, friction-type devices, and 2-step SA viscous dampers was proposed by Madhekar and Jangid [13]. The same authors [14] also proposed a pseudonegative stiffness control algorithm with SA dampers and the adoption of variable frequency pendulum isolators (VFPI), installed between deck-end and abutments [15]. Narasimhan [16] presented a direct adaptive control scheme for active control using the combination of a proportional-derivative controller with a neural network, which does not need a priori knowledge of the nonlinear dynamics of the bridge and of its parameters, according to direct Lyapunov approach. In contrast, a so-called turbo-Lyapunov approach control algorithm that utilizes the relationship between the absolute velocity of the MR dampers and control signal was developed by Cha and Agrawal [17].

The effectiveness of passive techniques for vibration control generally depends on how similar the characteristics of the actual seismic load are with respect to the design earthquake. The semiactive (SA) strategies are instead based on the use of variable stiffness and/or damping devices, able to adapt and optimize their mechanical response in real-time during the dynamic excitation. For such reasons, they are typically more effective than the passive ones, even if they are more difficult to implement and manage. Indeed, SA control techniques usually rely on the use of feedback control algorithms that require a real-time measurement of the structural response to instantaneously calibrate variable devices and, in turn, a complex framework of sensors and processing hardware to provide that. Despite many experimental investigations [1822] and some real applications [23] having shown the high effectiveness of the SA control strategy to mitigate structural vibrations, it is yet to be proven that the reliability of the SA system is so much higher than that of alternative control techniques so as to justify its complexity. Conversely, doubts about the durability and reliability of these devices over time have recently been downsized [24].

In the last few years, the authors of this paper made efforts to define a “smart passive” control technique for the protection of structures. They aimed to find a trade-off between the ease of use of passive devices and the effectiveness of more complex (semiactive) approaches to reduce earthquake-induced structural vibrations [2528]. The idea is based on the passive use of time-varying property devices [29, 30]. Their calibration is commanded some seconds before an earthquake hits the structure, exploiting predictive information about the magnitude of the event provided by a Seismic Early Warning System (SEWS). The characteristics of earthquakes that really strike a given site can be, as known, even far from those expected on a probabilistic basis. In such cases, the performance of a “pure” passive control strategy can be worse than the design expectations, even leading to undesired effects. The proposed smart approach for giving supplemental damping allows avoiding this kind of problem. Furthermore, recent research [28] demonstrates the robustness and the fail-safety of such technique.

SEW systems experienced drastic improvement and wide diffusion in many active seismic regions of the world in the last few decades [31]. They are currently operating in Japan [3235], Taiwan [36, 37], and Mexico [38]. Many other systems are under testing in other regions of the world, such as California [3942], Turkey [43], Romania [44], and China [45]. In southern Italy, the early warning system PRESTo [46] (Probabilistic and Evolutionary Early Warning SysTem) has been under testing since December 2009. It is currently used to monitor the Apenninic fault system and to detect small-to-moderate-size events in the area where the MW 6.9 1980 Irpinia earthquake occurred.

Among other functions, a SEWS is able to provide an estimate of the peak ground accelerations (PGA) of an earthquake in a given site based on the frequency content of the P-waves and the use of attenuation laws. In this manner, the magnitude prediction is made available from the SEWS at the site some seconds before the destructive S-waves reach that location [4752].

Herein, the use of MR dampers as passive devices, calibrated once according to the probable PGA of the incoming earthquake as provided by a SEWS installed at the site and remaining unchanged for the overall duration of the seismic excitation, is investigated. Concerning the response time of the system, in [47] it is showed that a seismic network for early warning can detect accelerations in the fault area and estimate the PGA at the structure’s site in 10–13 s with a relatively high reliability. Therefore, the proposed system can be considered effective in all cases where the sensor network of the SEWS is closer to the epicenter than the infrastructure to protect by roughly 10 km or more. Then, the time needed for the calculation of the optimal voltage, once known as the PGA, is almost null. Finally, a recent experimental study [53], with reference to real MR devices, manufactured in Germany, demonstrated, via tests of promptness, that, using and properly tuning adequate electric hardware, the response time of such type of smart devices can be comfortably bounded to only 8–10 ms.

The proposed approach, preliminarily explored in [27, 28], is herein fully formalized and designed for potential use in real applications.

The core issue of the proposed strategy is the design of the control logic that has to drive the MR dampers via the SEWS information. A specific design procedure has been herein addressed for the first time. The idea of realizing a design procedure for “regional” control algorithms, that is, control logic optimized to be used in specific areas characterized by homogeneous seismicity, is proposed. The latter is based on the results of several nonlinear dynamic simulations under natural earthquakes recorded in the considered area and on the use of optimization procedures.

The benchmark highway bridge, cited above, has been herein referred to as a case study to show the practical application and the effectiveness of said design procedure. Two different regional controllers have been specifically designed for Italy and California.

2. The Proposed Approach

The smart passive control strategy herein proposed to mitigate the seismic risk of bridges is based on the use of the following main components:(1)Variable dissipative devices.(2)A seismic early warning network working in the area where the structure is located.(3)A control algorithm able to drive the variable dampers according to the preliminary information about an incoming earthquake provided by the early warning system.

Assuming that the dissipative devices have been proportioned (in terms of maximum reacting force) and positioned in the structure according to the criteria usually adopted for passive dampers and that a SEWS actually serves the region of interest, element number 3 definitely emerges as the core of the procedure and, thus, of the present research. It requires the implementation of a specific, unedited design procedure addressed to maximize the effectiveness of the entire control system in terms of structural response reduction. The ambitious goal is to calibrate such a design procedure to generate “regional” controllers, that is, control logic that can effectively drive the smart control devices regardless of where the structure is actually positioned inside the given region.

2.1. A Design Procedure for Smart Passive Regional Control Algorithms

The design procedure herein proposed can be summarized with the following step-by-step scheme:(1)Definition of a set of natural regional accelerograms.(2)Design of an optimal (pure) passive control strategy to be assumed as the benchmark case.(3)Definition of a parametric control law for the smart passive control strategy.(4)Definition of the final algorithm by selecting optimal values for the involved parameters.

Details about the goal of each step and possible ways to manage specific issues to push forward with the procedure are discussed in the following sections.

2.1.1. Definition of a Set of Natural Regional Seismic Accelerograms

It should be a set corresponding to natural seismic events registered in the region of interest. The set has to be large enough to include earthquakes very different from each other with regard to the distance to the fault, magnitude, and peak values of accelerations, velocity, and displacement and to well cover the range of typical values for such parameters in that region. To give an idea, when the specific location of a given structure is considered (rather than an entire region), many technical codes (e.g., Eurocode 8 [56]) require a minimum of 3 earthquakes to be considered for time-history structural analyses. Actually, these codes strongly drive the designer to include in the set at least 7 seismic inputs. When an entire seismic region is considered, the authors consider that the set should be at least three times larger, depending on the extension of the area and on how varied the characteristics are (magnitude, distance to the fault, frequency content, etc.) of the seismic events expected.

2.1.2. Design of an Optimal (Pure) Passive Control Strategy

An optimal (pure) passive control strategy for the structure, to benchmark the smart passive strategy, has to be designed. This is recommended to correspond to a specific calibration, defined once and for all, of the variable dampers the user intends to use for smart control. The selection should preferably be performed with the support of an automatic decision-making tool to make the final choice as objective as possible. The TOPSIS method (Technique for Order Preference by Similarity to Ideal Solution) [5759] is herein suggested for that purpose. Actually, a wide comparative analysis performed among several multicriteria decision-making procedures from the literature established that TOPSIS is one of the most suitable procedures to solve civil engineering decision problems [60]. Moreover, it has been applied in the past with success to analogous problems relative to the seismic upgrading of structures [61].

The set of criteria to be used to compare the alternative passive strategies has to correspond to the main performance indices for the case under examination and should involve at least one pair of conflicting criteria (i.e., criteria that, considered separately from the others, lead to diametrically opposed decisions).

2.1.3. Definition of a Parametric Smart Passive Control Law

The control algorithm must establish what the optimal calibration of the installed variable dampers is according to an intensity measure of the incoming earthquake, the latter being forecasted by the Seismic Early Warning System. Preliminary studies performed by the authors [27, 28] led to the definition of an effective control law suitable when variable dampers based on magnetorheological fluids are used and when the spectral accelerations at the fundamental period of the structure is used as a measure of the magnitude of the earthquake. The latter accelerations is suggested to be derived, once the SEWS provides the expected PGA of the incoming earthquake, from the elastic damped response spectrum defined according to Eurocode 8 [56] rules and, therefore, to the above PGA value, the soil type, and the structural damping (Figure 1(a)). The above cited control law is that in (1), where is the voltage to be supplied to the MR dampers, as established by the algorithm according to , whereas the three parameters of the configuration involved are as follows:(i) is expressed in (gravitational accelerations, as ) and determines the abscissa of the point of the maximum slope of the curve in Figure 1(b).(ii), also expressed in , determines the magnitude of the above slope.(iii) is the maximum voltage set to be given to the MR devices.

This formulation has been assumed because it corresponds to a smooth curve, giving values of from 0 to (Figure 1(b)):

2.1.4. Selection of Optimal Values of the Involved Parameters: Final Algorithm

An optimization procedure is recommended to calibrate all of the parameters involved in the control law. For instance, when MR dampers are adopted for control and (1) is assumed as the control law, the three parameters , , and have to be defined. These depend on the seismic region.

Herein, the TOPSIS procedure is again suggested to achieve the above goal, that is, to compare the amount of structural response reduction of several combinations of values for , , and to find the “best” among them. To do that, first the range of values for each of the parameters and the criteria to be used for judgment must be defined. More details about such aspects will be given in the following sections in which a practical application of the method to a case study structure will be shown. Here, it is worth underlining the need for involving criteria that reflect the peculiar features of a semiactive control system. For instance, not only the mean value of each performance index evaluated for all of the earthquakes of the set but also the standard deviation of those values with respect to the mean should be considered. Actually, a semiactive strategy, adaptive by definition, should always ensure less variability of the structural response against even very different seismic inputs.

2.1.5. The TOPSIS Decision-Making Tool: Summary of the Procedure

Herein, a brief summary of the TOPSIS procedure [5759], suggested in Sections 2.1.2 and 2.1.4, is presented for the convenience of the reader.

Let be a finite group of alternative solutions for a decision-making problem and a finite set of criteria according to which performance of each feasible action must be assessed. Solving the multicriteria decision problem consists of determining the optimal solution among alternatives, that is, the one with the highest degree of desirability with respect to all of the criteria. The first step consists in the evaluation of all the alternatives according to each criterion. Generally speaking, qualitative criteria can be involved in the decision process. This kind of criteria, by definition, requires evaluation through linguistic judgments. As a consequence, in these cases, a further step, consisting in the conversion of these qualitative evaluations in equivalent crisp numbers, is needed, with procedures available in literature. At the end, the so-called decision matrix (having by dimensions) may be composed, where the generic element (th row, th column) is the performance of the alternative in respect of criterion (Table 1). Then the method needs the definition of a weight for each criterion expressing the relative importance of it in respect of the others. This is one of the most critical phases of the decision procedure requiring a synthetic and quantitative measure of the decision maker’s preference about each performance target. However, weighting of criteria is unsuitable for decision problems where criteria implicitly have the same importance. This is the case of the application herein proposed that involves two criteria, both related to structural performance.

The TOPSIS method is based on the geometrical concept that the best alternative should have the shortest distance to an ideal solution () and the farthest distance to negative-ideal one (). Let indicate the performance measure of the th alternative according to the th criterion . The normalization of the values must first be done according to (2). Let indicate the normalized value of

The two opposite fictitious solutions and , as for the real alternatives , are defined by values representing the (normalized) performances according to the criteria. In particular, the ideal solution is obtained by taking for each criterion the “best” performance among the alternatives, whereas the negative-ideal solution is obtained by taking the “worst” values. It is worth noting that the best value among the performances corresponds to the minimum or maximum value depending on what type the criterion is, that is, a “cost” or “benefit” criterion, respectively.

Each of the alternatives, real and fictitious ( and ), can be represented by a point in the -dimensional space defined by the axes along which the normalized performances are measured according to each of the criteria. Figure 2 reports, as an example of such a representation, a hypothetical decision problem involving 4 alternatives and 3 criteria. Indicating with and the distances of each option to and , respectively (equation (3)), the ranking of alternative solutions is made according to their relative closeness to , evaluated as in (4): It is worth noting that is equal to 1 if coincides with , it is equal to 0 if coincides with , and it is between 0 and 1 in the other cases. The best alternative is the one with the highest value.

3. Application of the Proposed Approach to a Case Study

The approach herein proposed to design the smart passive control for the seismic protection of structures has been tested through a practical application to a case study. The structure is a highway bridge proposed as a benchmark structural control problem in [24]. It is located in Orange County, southern California, and consists of a two-span continuous cast in situ prestressed concrete. The total length of each span is 58.5 m, whereas the transversal prestressed support beam has a length of 31.4 m. This central support is linked to two columns that are 6.9 m high. The mass of the deck is approximately 3200 tons, while the total mass of the bridge is 4200 tons (Figure 3). The bridge deck is seismically isolated by four nonseismic elastomeric pads at each abutment, whereas eight fluid dampers are installed between the end abutments and the deck to reduce seismic response. However, in the evaluation model, lead rubber bearings (LRB) are used to replace the eight traditional nonseismic elastomeric pads (Figure 4). The first mode of the structure is torsional with a natural period  s. This configuration will be used for comparison to establish the effectiveness of the control system proposed. It will be referred to as the “uncontrolled” structure.

In the above papers introducing the benchmark bridge, the design of an SA control strategy is presented, considering a total of 20 MR dampers installed between the deck and the abutments and at the top of the piers of the central support. The maximum voltage for the devices is 10 V. The capacity in terms of reacting force is 1000 kN. Herein, the same devices (further details about them can be found in the cited articles) are used to realize the smart passive control as described in the previous section.

Such structure has been adopted as a reference case for the design of regional smart passive control algorithms. Two seismic regions have been considered: Italy and California. The two cases will be described in parallel in the following sections, according to the step-by-step procedure discussed in Section 2.1.

3.1. Definition of the Set of Natural Regional Accelerograms

According to the criteria discussed in Section 2.1.1, a set of 30 natural accelerograms has been selected for each of the 2 seismic regions. All are recorded on soil type B according to the Eurocode 8 [56] classification. They have been assumed as input for nonlinear time-history analyses of the bridge. The analyses have been performed using the MATLAB code made available by the above authors of the benchmark papers [24]. For the excitation of the longitudinal (EW) and transverse (NS) directions of the bridge, both components have been used simultaneously. The main characteristics of the earthquake ground motions are shown in Tables 2 and 3 for Italy and California, respectively. They cover a wide range of magnitudes and PGAs (0.06 to 0.66 g for Italy, 0.08 to 0.89 g for California), as recommended above. It is worth noting that the benchmark problem cannot consider vertical seismic accelerations. For this reason, vertical components of the selected earthquakes have not been mentioned in this paper. The Italian seismic inputs have been downloaded from the Italian accelerations Archive (ITACA [54]), whereas the Californian earthquakes are sourced from the Pacific Earthquake Engineering Research Center (PEER [55]).

3.2. Design of the Optimal (Pure) Passive Control Strategy

Several passive control strategies have been compared, separately, for each of the two regions. Each strategy corresponds to a different passive use of the MR dampers described above. Voltage values within the operation interval of the devices,  V, with a step of 0.05 V have been considered, leading to a total of 201 different passive configurations. The number of response parameters herein assumed to explore the proposed strategy and the effective use of the optimization procedure it involves have been limited to two, each representative of the main groups of usual response indexes, that is, forces and displacements. Nevertheless, future developments of this work may take into consideration additional response parameters. Those assumed herein are(i), the peak overturning moment at the base of the piers in the controlled structure normalized by the corresponding value obtained for the uncontrolled structure subjected to the same seismic input;(ii), the peak displacement at the midspan of the controlled structure normalized by the corresponding value of the uncontrolled structure under the same earthquake.

The TOPSIS procedure is applied assuming two evaluation criteria, and , based on the values of the two above indices, respectively. More in detail, the performance measure of the th alternative according to the th criterion is calculated as follows:where is the th performance index evaluated for the th alternative in response to the th earthquake (). Therefore, the th criterion takes into account the mean value of the th performance index for all of the earthquakes of the set.

The TOPSIS method is applied to both of the decision problems relative to the Italian and Californian regions, leading to the following outcomes:(i)Italy. The voltage 3.75 V resulted in the highest relative closeness (0.94) to the ideal solution; therefore, it has been assumed to be representative of the optimal passive damper for the Italian earthquakes. The performance indices are, in order, 0.87 and 0.67, and therefore the optimal passive control strategy leads, on average, to a 13% reduction (with respect to the uncontrolled case) of the overturning moment demanded of the piers and to a 33% reduction of midspan displacement.(ii)California. The voltage 10.00 V (the highest allowable value) resulted in the highest relative closeness (0.98) to the ideal solution; therefore, it has been assumed to be representative of the optimal passive damper for the Californian earthquakes. The performance indices are 0.79 and 0.58, and therefore the optimal passive control strategy leads, on average, to a 21% reduction of the overturning moment demanded of the piers and to a 42% reduction of midspan displacement.Figures 5 and 6, for Italy and California, respectively, show the values of the indices and for each of the 30 earthquakes and each of the 201 passive dampers tested. The black dots highlight the performance of the optimal passive dampers.

3.3. Design of the Smart Passive Control Strategy

For both the Italian and Californian cases, several numerical analyses have been performed to calibrate the smart passive control strategy, that is, to find the optimal value for the parameters (namely, , , and ) involved in the assumed analytical expression (equation (1)) for the control law. Actually, the value of has been established a priori, looking at the results of the previous step in which, to find the optimal passive configuration, the variability of the response according to the voltage given to the MR dampers has been investigated. More in detail, the value of should always be defined so as to make the range inclusive of the value found to be optimal for a pure passive control strategy, against the whole set of earthquake records (herein it is 3.75 V and 10.00 V for the two regions, Italy and California, resp.). Moreover the interval should be large enough so as to strictly include all the values of voltage found to be ideal for each single record of the set, excluding the greater values, although included in the working range of the devices. Actually, it has been proved that if the operating range for the algorithm is oversized, the performance of the smart passive technique can worsen. Finally, with reference to the two regions herein examined, the following conclusions have been drawn:(i)For the Italian case, given that the optimal passive voltage is equal to 3.75 V and because none of the records has called for the adoption of a voltage value higher than 4 V, it has been assumed equal to 4 V.(ii)For the Californian case, because the optimal passive voltage was found to be 10 V, it has been assumed that is just equal to 10 V (i.e., the upper bound of the operating range of the MR devices).

A total of 961 combinations of values for and have been tested, both assumed to be within the range  g with a step of 0.02 g. These intervals have been preliminarily individuated because they include values of and that lead to an acceptable shape (see Figure 1(b)) of the control algorithm, such that the voltage actually varies from 0 to according to the values of the spectral accelerations demand expected at the region.

As highlighted in Section 2.1.4, to calibrate the control law, the evaluation criteria addressed to maximize the performance are peculiar for a semiactive control technique (e.g., a limited variability of the structural response against even very different seismic inputs) and are strongly recommended to effectively achieve the goals of the strategy herein proposed. For this reason, additional criteria with respect to those adopted to design the optimal passive strategy have been considered, for a total of six: measures the mean value of the performance index (peak overturning moment at the base of the piers) for all of the earthquakes of the set. measures the mean value of the performance index (peak midspan displacement) for all of the earthquakes of the set. measures the standard deviation of the performance index for all of the earthquakes of the set. measures the standard deviation of the performance index for all of the earthquakes of the set. measures the number of earthquakes over the total (30) for which the smart passive strategy leads to a performance index greater than 1 (i.e., to a pier overturning moment greater than in the uncontrolled case). measures the number of earthquakes over the total (30) for which the smart passive strategy leads to a performance index greater than 1 (i.e., to a midspan displacement greater than in the uncontrolled case).

Each of the above 961 possible calibrations of the control law has been evaluated according to the set of 6 criteria, finally allowing ranking of those alternatives by means of the TOPSIS method. The resulting optimal (, ) combinations are(i) and  for Italy (with  V);(ii) and   for California (with  V).

The so-defined control algorithms for the Italian and Californian regions are expressed in (6) and (7) and graphically shown in Figure 7. The structural performances, in terms of and , achieved by the smart passive strategies are shown in Figures 8 and 9, together with those corresponding to the passive cases, for comparison. Such comparison can also be made analytically by reading Table 4, in which the evaluation of both passive and smart passive strategies according to the above six criteria is reported.

In Italy,

In California,

The following comments can be made in reference to the data in Table 4:(i)Criterion : both pure passive and smart passive control strategies lead to a significant reduction of the bending moment demand on the pier (approximately 20% on average).(ii)Criterion : the optimal passive strategy leads to an average reduction of 33% and 42% with respect to the uncontrolled case for Italy and California, respectively, while the smart passive strategy leads to a still significant reduction, even if it is lower (26% for both regions). This was expected because the optimal passive voltages (3.75 V for Italy and 10.00 V for California) correspond to a high damping setting for the MR. Roughly speaking, considering that the magnetorheological effect due to voltage is strongly nonlinear with the voltage, the MR devices set at those levels of voltage behave as very “stiff” links between the deck and the abutments, leading to a displacement reduction that is hardly improvable.(iii)Criteria , : the smart passive strategy strongly reduces the variability of the response reduction with respect to the seismic input; actually, the standard deviations of both indices and evaluated for both sets of Italian and Californian earthquakes are significantly lower than those corresponding to the passive strategy;.(iv)Criteria , : the smart passive strategy further strongly reduces the occurrence of cases for which the control technique worsens the structural performance in comparison to the uncontrolled system. This is in terms of both the bending moment on the piers and (even more so) the displacement demand.

These comments aim to conclude the adopted optimization procedure performed correctly, in the sense that it was able to lead to the definition of smart strategies having the main peculiar features of a semiactive control system: a strongly reduced variability of the response against different earthquakes and a drastic reduction of the incidence of undesired responses (i.e., controlled response higher than uncontrolled one), with average values of the performance indices not so far from those already achievable by a (simpler) pure passive control system.

From Figures 8 and 9, it is also worth noting how the performances of the smart control strategy (circles) are “positioned” for each earthquake of the 2 sets in comparison with those of the optimal passive strategy (dots) and, for completeness, also with those of all of the possible passive strategies (grey lines) based on the use of the devices in question. More in detail, it is interesting to observe how the “bandwidth” of the and values is significantly reduced for the smart passive strategy and how the trend is “pushing down” the values corresponding to the worst performances (i.e., indices greater than 1) of the optimal passive technique.

4. Conclusions

A smart passive control technique for the seismic protection of structures, based on the use of variable MR-fluid-based dampers and exploitation of a SEWS, has been proposed. The design procedure needed to implement such a system in a real case has been generated and also practically applied to two case studies.

The numerical results of the above application demonstrate the high effectiveness of the proposed procedure in reducing the structural demand due to strong earthquakes. Regional control algorithms played a central role in accomplishing that. Full achievement of all of the typical goals for a semiactive control strategy has been observed. With reference to the case study applications, it was demonstrated that the proposed control system allows for significant reductions of the average structural response (20–25%) and, above all, that it is able to strongly reduce the variability of the response with the seismic input. Finally, in only a few cases (roughly one in ten) were the performances worse than those of the uncontrolled case. Even more importantly, in such critical cases, the proposed strategy led to performance index values that were only slightly greater than one, thus allowing for the conclusion that even when, in rare cases, the smart control is not beneficial, it is still definitely far from being detrimental to the structure, which cannot be said about pure passive systems.

Even if designed with reference to a given case study, the authors believe the regional control algorithms are potentially valid to drive variable dampers in effectively protecting any structure from earthquakes. Obviously, the number and strength capability of the MR devices obviously have to be defined according to the specific features of the case. A preliminary confirmation of such interpretation recently came from the satisfactory results achieved using the Italian regional controller applied to a real bridge located in southern Italy [62].

Competing Interests

The authors declare that they have no competing interests.

Acknowledgments

The work behind this paper has been financially supported by the consortium Reluis with a 2014-18 Grant by the Protezione Civile (Italian Emergency Agency) and by the University of Naples “Parthenope” with a grant within the call “Support for Individual Research for the 2015-17 Period” issued by Rectoral Decree no. 727/2015. The support of both is gratefully acknowledged.