A Method for Aileron Actuator Fault Diagnosis Based on PCA and PGC-SVM
Table 15
The cross validation rate and test rate with regard to different dimension of inputs.
Dimension
CV rate
Test rate
1
76.73%
76.75%
2
82.08%
83.05%
3
89.37%
89.87%
4
96.63%
96.50%
5
98.88%
99.01%