Research Article

A Method for Aileron Actuator Fault Diagnosis Based on PCA and PGC-SVM

Table 3

Parameters of servo valve.

SV00-1: all real parametersUnitValue

Ports P to A flow rate at maximum valve openingL/min150
Ports P to A corresponding pressure dropBar20
Ports P to A critical flow number (laminar turbulent)Null1000
Ports B to T flow rate at maximum valve openingL/min150
Ports B to T corresponding pressure dropBar20
Ports B to T critical flow number (laminar turbulent)Null1000
Ports P to B flow rate at maximum valve openingL/min150
Ports P to B corresponding pressure dropBar20
Ports P to B critical flow number (laminar turbulent)Null1000
Ports A to T flow rate at maximum valve openingL/min150
Ports A to T corresponding pressure dropBar20
Ports A to T critical flow number (laminar turbulent)Null1000
Working density for pressure drop measurementkg/m3850
Working kinematic viscosity for pressure drop measurementcSt60
Valve rated currentmA1
Valve natural frequencyHz500
Valve damping ratioNull0.8
Deadband as fraction of spool travelNull0