Research Article
A Method for Aileron Actuator Fault Diagnosis Based on PCA and PGC-SVM
Table 3
Parameters of servo valve.
| SV00-1: all real parameters | Unit | Value |
| Ports P to A flow rate at maximum valve opening | L/min | 150 | Ports P to A corresponding pressure drop | Bar | 20 | Ports P to A critical flow number (laminar turbulent) | Null | 1000 | Ports B to T flow rate at maximum valve opening | L/min | 150 | Ports B to T corresponding pressure drop | Bar | 20 | Ports B to T critical flow number (laminar turbulent) | Null | 1000 | Ports P to B flow rate at maximum valve opening | L/min | 150 | Ports P to B corresponding pressure drop | Bar | 20 | Ports P to B critical flow number (laminar turbulent) | Null | 1000 | Ports A to T flow rate at maximum valve opening | L/min | 150 | Ports A to T corresponding pressure drop | Bar | 20 | Ports A to T critical flow number (laminar turbulent) | Null | 1000 | Working density for pressure drop measurement | kg/m3 | 850 | Working kinematic viscosity for pressure drop measurement | cSt | 60 | Valve rated current | mA | 1 | Valve natural frequency | Hz | 500 | Valve damping ratio | Null | 0.8 | Deadband as fraction of spool travel | Null | 0 |
|
|