Vibration reduction ratio of TMD with different sag-span ratio (%).

ResponseLine sag (m)Sag-span ratioWind angle of 90°Wind angle of 0°

Axial force500.04519.629.7
550.04917.228.3
600.05419.130.1

Displacement500.0454.25.7
550.0493.86.2
600.0544.65.6

Acceleration500.04546.160.1
550.04950.261.3