Research Article
Correlation Coefficient of Simplified Neutrosophic Sets for Bearing Fault Diagnosis
Table 6
Fault diagnosis results based on the correlation coefficient of SNSs, SVM, BP, and GA-BP.
| Diagnosis method | Diagnosis accuracy rate (%) | Average accuracy (%) | Healthy | Outer race fault | Ball fault | Inner race fault |
| SNS | 93.3 | 93.3 | 83.3 | 100 | 92.5 | SVM | 90 | 93.3 | 76.7 | 83.3 | 85.8 | GA-BP | 100 | 80 | 70 | 90 | 85 | BP | 90 | 70 | 50 | 90 | 75 |
|
|