Research Article

Nonlinear Seismic Behavior of Different Boundary Conditions of Transmission Line Systems under Earthquake Loading

Table 2

Ground line and conductor properties of the tension type.

TypeGround lineConductor
JLB40-150LGJ-400/35LGJ-240/30

Outside diameter (m)
Area (m2)
Young’s modulus (MPa)1036006500073000
Poisson’s ratio0.30.30.3
Density (Kg/m3)4705.23172.33341.7