Research Article

Shaking Table Tests on Earthquake Response Characterization of a Complex Museum Isolated Structure in High Intensity Area

Table 12

Dynamic characteristics test results of isolated structure model.

ModeDescription12345678AVE

Isolated structure modelInitial (Hz)3.893.894.2519.1121.9442.8157.3269.00
Minor 8 (Hz)3.893.894.2519.1121.9442.8157.3269.00
Variation (%)0.000.000.000.000.000.000.000.000.00
Moderate 8 (Hz)3.893.894.2518.4021.0542.8157.3268.64
Variation (%)0.000.000.00−3.70−4.100.000.00−0.50−1.00
Major 8 (Hz)3.893.894.2518.4021.0542.2857.3268.64
Variation (%)0.000.000.00−3.70−4.10−1.200.00−0.50−1.20

Base-fixed structure modelInitial (Hz)8.499.9110.9714.8615.2147.0633.7939.81
Minor 8 (Hz)8.149.5510.9714.1514.5146.2331.8438.92
Variation (%)−4.20−3.600.00−4.80−4.60−1.80−5.80−2.20−3.40
Moderate 8 (Hz)7.079.2010.2613.814.5145.2930.7837.51
Variation (%)−16.70−7.10−6.50−7.10−4.60−3.80−8.90−5.80−7.60
Major 8 (Hz)6.027.088.4911.6812.0342.6427.9533.61
Variation (%)−29.20−28.60−22.60−21.40−20.90−9.40−17.30−15.60−20.60