Comparison of first four eigenfrequencies () in Hz of unloaded plate with attached discrete point masses.

ModeUnloaded plate (Figure 2(a))Plate with one discrete point mass (Figure 2(b))% variation in natural frequencyPlate with two discrete point masses (Figure 2(c))% variation in natural frequencyPlate with four discrete point masses (Figure 2(d))% variation in natural frequency

1st8773.02216.06684.4972.87783.5583.956
2nd193189.871.621177.857.849174.559.559
3rd241235.142.431229.324.846224.636.792
4th345310.889.889284.5417.524281.5418.394