Verification with measured and calculated velocities at different studied positions (unit: mm/s) [33].

Studied positionsABCD

Positive peak valuesMeasured velocities0.4498 0.5231 0.6355 0.7075
Calculated velocities0.4434 0.5105 0.6284 0.7000
Error (%)1.42 2.41 1.12 1.06

Negative peak valuesMeasured velocities−0.4527 −0.5589 −0.6648 −0.7452
Calculated velocities−0.4609 −0.5982 −0.6989 −0.7621
Error (%)1.81 7.03 5.13 2.27