Research Article

The Performance of Resistance Progressive Collapse Analysis for High-Rise Frame-Shear Structure Based on OpenSees

Table 1

Parameters of structural material.

Item nameBeamsColumnsShear walls

ConcreteC30 ( = 20 MPa)C40 ( = 26.8 MPa)C40 ( = 26.8 MPa)
Longitudinal reinforcing steelHRB335HRB400
( = 335 MPa)( = 400 MPa)
Hoop reinforcing steelHPB235 ( = 235 MPa)