Research Article

Experiment and Simulation Analysis on Noise Attenuation of Al/MF Cylindrical Shells

Table 2

Comparison of acoustic modes achieved by analytical method and simulation computation.

Mode

Analytical value/Hz151.1192.2244.5302.2317.9352.1358.2398.0
Simulation value/Hz151.1191.3243.8302.2317.2351.4357.7398.1