Research Article
Field Tests to Investigate the Penetration Rate of Piles Driven by Vibratory Installation
Table 2
Dimensions and sectional properties for steel sheet piles chosen in test.
| Type | mm | mm | mm | cm2 | ā cm | cm4 | cm3 | cm | kg/m |
| Larssen-III | 400 | 125 | 13.0 | 76.42 | 137.85 | 2,220 | 223 | 5.39 | 60.0 | Larssen-IV | 400 | 170 | 15.5 | 96.99 | 154.80 | 4,670 | 362 | 6.94 | 76.1 | Larssen- V | 500 | 200 | 24.3 | 133.8 | 175.13 | 7,960 | 520 | 7.71 | 105 |
|
|