Research Article
Field Tests to Investigate the Penetration Rate of Piles Driven by Vibratory Installation
Table 4
Summary of field tests.
| Series | Test site | Pile type | Pile length (m) | Clutch | Driving system | Operator | Penetration time (s) |
| A | 1# | Larssen-IV | 3 | Without | EX450 | Skilled | 10.48 | B | 1# | Larssen-IV | 6 | Without | EX450 | Skilled | 14.08 | C | 1# | Larssen-IV | 9 | Without | EX450 | Skilled | 19.37 | D | 1# | Larssen-IV | 12 | Without | EX450 | Skilled | 44.36 | F | 1# | Larssen-V | 9 | Without | EX450 | Skilled | 23.12 | G | 1# | Larssen-III | 9 | Without | EX450 | Skilled | 18.59 | H | 1# | Larssen-IV | 9 | With | EX450 | Skilled | 37.46 | J | 2# | Larssen-IV | 12 | Without | EX450 | Skilled | 34.26 | K | 2# | Larssen-IV | 12 | Without | EX470 | Skilled | 28.72 | L | 2# | Larssen-IV | 12 | Without | EX450 | New | 40.22 | Q | 3# | Larssen-IV | 12 | Without | EX450 | Skilled | 479.41 | R | 3# | Larssen-IV | 12 | Without | EX470 | Skilled | 644.11 | S | 3# | Larssen-IV | 12 | Without | Free-hanging | Skilled | 672.41 |
|
|