Research Article

Pyroshock Acceleration Field Reconstruction in Temporal and Spectral Domains Based on Laser Shock Scanning and Iterative Decomposition and Synthesis Considering Stop Band Effects

Table 3

Measurement condition of laser shock for reconstruction of pyroshock on the disk type specimen.

Shock source (MHz)Filter (kHz)Number of samplesPRF (Hz)Scan area (mm)

Laser shock10.1~10051250Width = 136
Height = 104
Interval = 1