Research Article

Force Feedback Control Method of Active Tuned Mass Damper

Table 1

Simulation parameter settings.

System parameterValues

Main system mass100 kg
Natural frequency of main system40 Hz
Damping ratio of main system0.002
Damper mass1 kg
Natural frequency of damper40 Hz
Damping ratio of damper0.001