Research Article
A Study on Internal Explosion Testing of the “Rigid-Flexible-Rigid” Three-Layer Sealed Structure
Table 7
The strain peak of Model 1 at different measurement points (×10−6).
| Measurement points | Explosive payloads/ (kg) | 0.15 | 0.2 | 0.3 | 0.475 | 0.8 |
| A-H-1 | 115.36 | 143.70 | 226.83 | 335.22 | 792.13 | A-H-2 | 100.58 | 126.63 | 195.43 | 270.84 | 602.89 | A-H-3 | 4.61 | 7.62 | 9.73 | 19.232 | 41.25 | A-H-4 | 3.03 | 6.94 | 8.25 | 15.916 | 37.84 | A-J-1 | 46.29 | 61.81 | 92.55 | 166.22 | 251.91 | A-J-2 | 44.46 | 54.30 | 80.21 | 132.69 | 154.44 | A-J-3 | / | 4.57 | 6.23 | 8.828 | 16.57 | A-J-4 | / | 4.15 | 6.03 | 7.587 | 12.35 |
|
|