Research Article

A Study on Internal Explosion Testing of the “Rigid-Flexible-Rigid” Three-Layer Sealed Structure

Table 8

The strain peak of Model 2 at different measurement points (×10−6).

Measurement pointsExplosive payloads/ (kg)
0.150.20.30.4750.8

A-H-1110.94148.79200.8326.67674.23
A-H-2102.67121.41157.86259.09489.76
A-H-35.438.3710.2522.55944.26
A-H-43.927.018.5920.04438.69
A-J-140.5549.3589.06140.46240.07
A-J-238.0644.6552.04126.52205.14
A-J-32.044.227.569.36616.01
A-J-4/3.936.087.65713.58