Research Article

Damping Identification with Acceleration Measurements Based on Sensitivity Enhancement Method

Table 8

Identification results with 20% and 30% measurement noise.

Noise levelDamping ratioSensor set 1Sensor set 2
Proposed methodConventional methodProposed methodConventional method

20%0.00990.00990.00990.0155
0.01990.01990.02000.0214
30%0.00990.00790.00990.0180
0.01990.01950.02000.0220

Noise levelDamping ratioSensor set 3Sensor set 4
Proposed methodConventional methodProposed methodConventional method

20%0.01040.00820.01010.0115
0.02010.01950.02020.0205
30%0.01070.00730.01030.0122
0.02020.01920.02000.0208

Noise levelDamping ratioSensor set 5Sensor set 6
Proposed methodConventional methodProposed methodConventional method

20%0.01140.00890.00960.0112
0.02020.01950.01990.0204
30%0.01240.00830.00980.0119
0.20400.01920.02000.0207