Research Article
Damping Identification with Acceleration Measurements Based on Sensitivity Enhancement Method
Table 8
Identification results with 20% and 30% measurement noise.
| Noise level | Damping ratio | Sensor set 1 | Sensor set 2 | Proposed method | Conventional method | Proposed method | Conventional method |
| 20% | | 0.0099 | 0.0099 | 0.0099 | 0.0155 | | 0.0199 | 0.0199 | 0.0200 | 0.0214 | 30% | | 0.0099 | 0.0079 | 0.0099 | 0.0180 | | 0.0199 | 0.0195 | 0.0200 | 0.0220 |
| Noise level | Damping ratio | Sensor set 3 | Sensor set 4 | Proposed method | Conventional method | Proposed method | Conventional method |
| 20% | | 0.0104 | 0.0082 | 0.0101 | 0.0115 | | 0.0201 | 0.0195 | 0.0202 | 0.0205 | 30% | | 0.0107 | 0.0073 | 0.0103 | 0.0122 | | 0.0202 | 0.0192 | 0.0200 | 0.0208 |
| Noise level | Damping ratio | Sensor set 5 | Sensor set 6 | Proposed method | Conventional method | Proposed method | Conventional method |
| 20% | | 0.0114 | 0.0089 | 0.0096 | 0.0112 | | 0.0202 | 0.0195 | 0.0199 | 0.0204 | 30% | | 0.0124 | 0.0083 | 0.0098 | 0.0119 | | 0.2040 | 0.0192 | 0.0200 | 0.0207 |
|
|