Natural frequency of CIPS and MPCS.

PGA/gFrequency/Hz
First frequencySecond frequency
-direction-direction-direction-direction
MPCSCIPSMPCSCIPSMPCSCIPSMPCSCIPS

Initial6.195.1375.6925.0020.7527.9423.25
0.035 g4.815.125.135.6320.5620.1322.4423.5
0.07 g4.805.125.065.520.0619.8822.0023.25
0.14 g4.694.564.945.3719.6919.8821.0622.06
0.22 g4.264.134.444.8118.2518.1319.8120.94
0.40 g2.792.813.753.7514.1913.5616.2516.56
0.62 g2.311.943.002.6911.6310.0613.6313.00
0.80 g1.861.552.882.549.389.4213.1812.88