Research Article
An Underdetermined Blind Source Separation Method with Application to Modal Identification
Table 1
Identified results of the structure in experiment 1.
| ā | Modal | Reference [15] | SCA | Proposed method |
| Frequency (Hz) | 1st | 31.28 | 30.72 | 30.78 | 2nd | 216.5 | 215.6 | 215.6 | 3rd | 596.8 | 585.9 | 585.9 | 4th | 1115 | 1115.2 | 1115.3 |
| Dam (%) | 1st | 2.661 | 2.733 | 2.863 | 2nd | 0.511 | 0.508 | 0.505 | 3rd | 0.601 | 0.606 | 0.585 | 4th | 0.242 | 0.234 | 0.234 |
|
|