Research Article

Shaking Table Array Tests of an Ultra-High-Voltage Cup-Type Transmission Tower-Line System

Table 10

Transverse peak strain responses of the middle towers of the four models.

Test seriesSingle-tower model (με)Single-tower model with suspended lumped masses (με)Three-tower-two-line model (με)Five towers and four lines (με)

0.07 g artificial wave60.64840.01758.05257.997
0.07 g El Centro wave19.67717.10823.16919.698
0.07 g Taft wave37.27130.92235.83641.472
0.07 g average39.19929.34939.01939.722
0.21 g artificial wave192.680115.984147.565178.187
0.21 g El Centro wave65.08462.48665.14964.533
0.21 g Taft wave129.43188.464110.259118.373
0.21 g average129.06588.978107.658120.364
0.63 g artificial wave573.068359.498410.263469.876
0.63 g El Centro wave193.587174.849178.199197.560
0.63 g Taft wave384.188253.697298.134351.734
0.63 g average383.614262.681295.532339.723