Research Article

Automatic Evaluation of Internal Combustion Engine Noise Based on an Auditory Model

Table 3

Comparison of test results of two evaluation models.

ModelInputTraining accuracy (%)Test accuracy (%)

CNNAuditory spectrum97.3195.28
CNNL90.2589.13
CNNR88.5887.47
CNNS88.2287.13
CNNA90.2589.56
BPL, R, S, A90.1189.33