Research Article

Research on Fault Feature Extraction Method Based on NOFRFs and Its Application in Rotor Faults

Table 5

The amount of change of RI, Ne, Fe1, Fe2, Fe3, and Fe4 under different rub-impact clearances (μm).

Indexes10080604020

ΔRI0.29100.21320.05770.05660.0526
ΔNe0.01427.388 × 10−37.413 × 10−37.041 × 10−36.754 × 10−3
ΔFe12.771 × 10−31.700 × 10−31.810 × 10−31.807 × 10−31.803 × 10−3
ΔFe22.242 × 10−31.619 × 10−31.616 × 10−31.613 × 10−31.610 × 10−3
ΔFe33.949 × 10−48.183 × 10−58.164 × 10−58.150 × 10−58.135 × 10−5
ΔFe41.349 × 10−46.657 × 10−71.119 × 10−41.117 × 10−41.116 × 10−4