Research Article
Fusion of Vibration and Current Signatures for the Fault Diagnosis of Induction Machines
Table 12
Classification accuracy of the fusion scheme.
| ā | Faulty condition of the motor | Normal | BRB | MIS | IRF | ORF |
| Results of prediction | Normal | 15 | 0 | 0 | 0 | 0 | BRB | 1 | 18 | 1 | 0 | 0 | MIS | 0 | 0 | 15 | 0 | 0 | IRF | 0 | 0 | 2 | 18 | 0 | ORF | 2 | 0 | 0 | 0 | 18 |
| Accuracy (%) | 83.33 | 100 | 83.33 | 100 | 100 |
| Total accuracy (%) | 93.33 |
|
|