Research Article

Full-Scale Experimental Investigation of the Static and Dynamic Stiffness of Prestressed Concrete Girders

Table 2

Compressive strength test results of concrete.

Sample numberSample height (mm)Sample diameter (mm)Compressive strength (MPa)

Z1-1100.999.231.2
Z1-2100.199.831.8
Z1-3101.199.633.3
Z2-1101.799.635
Z2-2100.8100.227.8
Z2-3101.199.233.8
Z2-4101.5100.639.3
B1-1100.699.125.1
B1-2100.699.220.5
B1-3101.699.830.3